Ask Copilot
Section · km 2.4–4.9

IB-02 Quarry Siding – Smelter Yard

4 open observations. Last inspected 30 Sep 2026, next due 29 Nov 2026.

Condition score

High priority
72 /100 · 78 on 26 Aug
Rail
76
OBS-1034 visible corrosion · pending, half weight · −3.0
Sleepers
64
OBS-1032 potential sleeper cracking · confirmed · −12.0
Fasteners
66
OBS-1033 missing fastener · confirmed · −12.0
Ballast
75
OBS-1035 unusual trackside condition · pending, half weight · −1.5
Vegetation
79

Internal Ralliyo metric, not a regulatory rating. Open observations deduct points by priority (high 12, medium 6, low 3), scaled by severity; pending observations count at half weight.

AssetCategoryKmConditionOpen
FS-IB02-014-RFastener2.986—
FS-IB02-016-LFastener3.486—
RL-IB02-001Rail2.487—
RL-IB02-002Rail2.4871
SL-IB02-040Sleeper4.187—
FS-IB02-019-RFastener4.287—
VG-IB02-02Vegetation zone4.387—
SL-IB02-038Sleeper3.788—
FS-IB02-018-RFastener3.988—
SL-IB02-035Sleeper3.089—
FS-IB02-017-RFastener3.689—
VG-IB02-01Vegetation zone3.189—
SL-IB02-039Sleeper3.990—
FS-IB02-014-LFastener2.990—
BZ-IB02-01Ballast zone3.090—
SL-IB02-036Sleeper3.291—
FS-IB02-017-LFastener3.691—
FS-IB02-019-LFastener4.293—
FS-IB02-015-LFastener3.1941
FS-IB02-015-RFastener3.194—
FS-IB02-018-LFastener3.995—
SL-IB02-034Sleeper2.896—
SL-IB02-037Sleeper3.5961
SL-IB02-041Sleeper4.396—
FS-IB02-016-RFastener3.496—
BZ-IB02-02Ballast zone4.2961

Inspection history

InspectionSectionDateMethodImagesObservationsInspector
INS-2026-041IB-0230 Sep 2026Hi-rail vehicle · forward camera64M. Haddad

Maintenance

MNT-301 Replace cracked sleeper SL-IB02-037scheduled
MNT-302 Replace missing fastener assemblyin progress