Ask Copilot
Section · km 0.0–2.8

NC-01 Central – Northgate

1 open observations. Last inspected 12 Aug 2026, next due 11 Oct 2026.

Condition score

Normal
88 /100 · 88 on 26 Aug
Rail
90
OBS-1040 visible corrosion · confirmed · −1.5
Sleepers
89
Fasteners
88
Ballast
87
Vegetation
86

Internal Ralliyo metric, not a regulatory rating. Open observations deduct points by priority (high 12, medium 6, low 3), scaled by severity; pending observations count at half weight.

Condition trend

808590951 Jul29 Jul26 Aug23 Sep21 Oct25 Oct
AssetCategoryKmConditionOpen
SL-NC01-115Sleeper1.286—
FS-NC01-040-LFastener0.686—
FS-NC01-040-RFastener0.686—
SL-NC01-113Sleeper0.787—
SL-NC01-116Sleeper1.487—
FS-NC01-045-LFastener2.087—
BZ-NC01-01Ballast zone0.787—
RL-NC01-001Rail0.0881
FS-NC01-041-RFastener0.888—
SL-NC01-117Sleeper1.789—
FS-NC01-045-RFastener2.089—
VG-NC01-01Vegetation zone0.889—
VG-NC01-02Vegetation zone2.289—
FS-NC01-044-RFastener1.791—
SL-NC01-118Sleeper1.992—
SL-NC01-119Sleeper2.292—
SL-NC01-112Sleeper0.493—
FS-NC01-042-RFastener1.193—
FS-NC01-043-LFastener1.493—
FS-NC01-044-LFastener1.793—
FS-NC01-042-LFastener1.194—
FS-NC01-043-RFastener1.494—
SL-NC01-114Sleeper0.995—
BZ-NC01-02Ballast zone2.095—
RL-NC01-002Rail0.096—
FS-NC01-041-LFastener0.896—

Inspection history

InspectionSectionDateMethodImagesObservationsInspector
INS-2026-022NC-0112 Aug 2026Track walk · smartphone imagery31R. Okafor

Maintenance

No maintenance items.