Ask Copilot
Section · km 3.5–7.0

WC-02 Millbrook – Orton

1 open observations. Last inspected 30 Jul 2026, next due 28 Sep 2026.

Condition score

Normal
90 /100 · 90 on 26 Aug
Rail
92
Sleepers
91
Fasteners
86
OBS-1021 fastener deterioration · confirmed · −1.5
Ballast
91
Vegetation
90

Internal Ralliyo metric, not a regulatory rating. Open observations deduct points by priority (high 12, medium 6, low 3), scaled by severity; pending observations count at half weight.

Condition trend

8590951 Jul29 Jul26 Aug23 Sep21 Oct25 Oct
AssetCategoryKmConditionOpen
SL-WC02-091Sleeper6.286—
FS-WC02-034-LFastener5.686—
FS-WC02-035-RFastener6.086—
VG-WC02-01Vegetation zone4.586—
SL-WC02-084Sleeper4.087—
SL-WC02-088Sleeper5.388—
FS-WC02-032-RFastener4.988—
SL-WC02-085Sleeper4.389—
SL-WC02-090Sleeper5.989—
BZ-WC02-01Ballast zone4.489—
BZ-WC02-02Ballast zone6.089—
RL-WC02-002Rail3.590—
SL-WC02-089Sleeper5.691—
FS-WC02-032-LFastener4.9911
SL-WC02-087Sleeper5.092—
FS-WC02-033-RFastener5.392—
RL-WC02-001Rail3.593—
FS-WC02-030-LFastener4.293—
FS-WC02-031-LFastener4.594—
FS-WC02-035-LFastener6.094—
SL-WC02-086Sleeper4.795—
FS-WC02-031-RFastener4.595—
FS-WC02-033-LFastener5.395—
FS-WC02-034-RFastener5.695—
VG-WC02-02Vegetation zone6.295—
FS-WC02-030-RFastener4.296—

Inspection history

InspectionSectionDateMethodImagesObservationsInspector
INS-2026-019WC-0230 Jul 2026Track walk · smartphone imagery31L. Brandt

Maintenance

No maintenance items.